IEC electric motor range from size 132 up to size 355
MULTI-COMPONENTS
Bell-Housings
Bell-Housing
91
Introduction
10
Bell-Housings & Couplings sizing
Power Transmission
AUTOMATIC
MANUALLY
11
12
p.
BELL-HOUSINGS
& COUPLINGS
SOFTWARE FOR AUTOMATIC CALCULATION
Scan or click me!
The web-based software program will allow you to select the most suitable
MP Filtri’s Filters, in accordance with your process design requirements.
The program will automatically check your input design process prior to propose
you the acceptable solutions and create an output in PDF report style format.
The MP Filtri Selection Tool software program is easy to use with a exible fast
design method and provides improved layout formats with full descriptions.
The web-based tool is available at MP Filtri website at following link:
https://www.mpltri.com/tools/
The related, complete user guide is available as Manual and downloadable from
the “Download” section of MP Filtri website, as well as scanning the following
QR code
Introduction
11
BELL-HOUSINGS & COUPLINGS SIZING
A GUIDE TO SELECT THE CORRECT BELL-HOUSING AND DRIVE COUPLING MANUALLY
Pages 75 ÷ 81 for IEC Electric motor size 100-112 - LMC250
LMC 250 bell-housing with height ≥ 135.5 - LMC250AFSQ
The bell-housing code must be completed with pump drilling code (see pages 60-61).
For the specic case:
Spigot hole 82.55 - PCD 106.4 - Nr.2 holes M10 : Drilling code 060
Denitive bell-housing code LMC250AFSQ060
Pages 83 ÷ 89 for IEC Electric motor size 100-112 - LMS250
LMS 250 bell-housing with height ≥ 135.5 - LMS250AFSA
The bell-housing code must be completed with pump drilling code (see pages 60-61).
For the specic case:
Spigot hole 82.55 - PCD 106.4 - Nr.2 holes M10 : Drilling code 060
Denitive bell-housing code LMS250AFSA060
Bell-Housing’s length calculation
Case A
Solution with monobloc bell-housing series LMC/LDC
Case B
Solution with low noise bell-housing series LMS/LDS
- H = 60 + 18 + 57.5 = 135.5 mm (18 = Sp spider - see page 31)
- Choose type of bell-housing (LMC - LMS):
For monobloc bell-housing LMC/LDC series see pages 75 ÷ 81
For Low noise bell-housing LMS/LDS series see pages 81 ÷ 89
For Multi-components 2-3 bell housing series see pages 91 ÷ 111
Note:
The length of bell-housing must be ≥ than the length calculated (135.5 mm)
- Electric motor power/motor size
- Manufacturer and pump type
1 - Pump and motor shaft dimensions (see electric motor data sheet)
2 - Shaft and ange pump (see pump data sheet)
Example:
- Electric motor 2.2 kW - size 100-112
- Atos pump code PFE31 - Shaft 1
DATA REQUIRED
TO VERIFY:
IEC Electric motor dimension Hydraulic pump dimension
Ø28 - key 8
Ø19.05 - key 4.76
Ø250
60
57.5
9.5
Ø82.55
Ø106.4
Nr. 2 Ø11
code M05 see page 18
code G01 see page 18
Introduction
12
BELL-HOUSINGS & COUPLINGS SIZING
A GUIDE TO SELECT THE CORRECT BELL-HOUSING AND DRIVE COUPLING MANUALLY
Motor half-coupling (see page 26)
For IEC Electric motor size 100/112, the half-coupling is SGEA21M05060
Spider (see page 31)
For SGEA21, EGE2 - EGE2RR
(choose spider material on the base of the application, oil, temperature and cycle machine, etc.)
Pump half-coupling
Choose the drilling code - see pages 18-19 for shaft 19.05 - key 4.76 - code: G01
Pump half-coupling length = BH length - THK Spider - THK Spigot
LMC = 138 mm - 60 - 18 - 9.5 = 50.5 mm
LMS = 148 mm - 60 - 18 - 9.5 = 60.5 mm
LMC - Choose the half-coupling’s length at page 26 ≤ 50.5 mm.
LMS - Choose the half-coupling’s length at page 26 ≤ 60.5 mm.
LMC - Available length for SGEA21 = 50 mm
LMS - Available length for SGEA21 = 60 mm
Half coupling for LMC: SGEA21G01050
Half coupling for LMS: SGEA21G01050
Coupling selection
Note: for multi pumps we recommend to use a specic support on the base of the pump’s dimensions and weight.
Introduction
13
GENERAL INFORMATION NOISE
THEORY AND DEFINITION OF NOISE
From a health and hygiene standpoint, noise can be dened as an unpleasant
and undesirable sound, or an unpleasant and annoying or intolerable auditory
sensation (noise being any sound phenomena that may be accompanied by
sensations of disturbance and pain). By definition, acoustic phenomena are
oscillatory in character, propagated in a exible medium and causing pressure
variations at the points, and the areas adjacent to those points, through which
they pass.
2
1
SOUND
Technically considered, certain elements must be present simultaneously
for acoustic phenomena to occur:
- Sound source
- Transmission medium
- Receive
The electric motor and the pump, together with the drive coupling, are the
SOURCE OF THE NOISE. The Bell-housing is the noise transmission MEDIUM.
Depending on whether the monobloc bell-housing is a rigid or low noise type,
there will be variations in the exible properties of the transmission medium.
The acoustic phenomena are dissimilar in the two cases, given the differences in
pressure variation and particle displacement.
MOTOR AND PUMP UNIT
Noise is a particularly pervasive problem so much so that there have been statutory regulations in place now for some years, designed to limit harmful
occupational exposure.
Many of the machines used in industry today are equipped with oil-hydraulic systems, which happen to be a major source of noise.
RECEIVER
- Human ear
- Sound level meter
BELL-HOUSING
ELECTRIC MOTOR
PUMP
Bell-Housing
58
ASSEMBLY OF MOTOR AND PUMP UNIT
Low noise bell-housing will help to attenuate the transmission of vibrations and the emission of noise generated by the system.
Self-evidently, however, the mere adoption of a low noise bell-housing will achieve little unless the motor and pump are correctly installed on the machine
or on the tank of the hydraulic power unit.
Should be followed in order to achieve best possible results and correct installation:
1
MOTOR AND PUMP UNIT MOUNTED
HORIZONTALLY ON OIL TANK LID
- The suction pipe attached to the pump must be rigid and tted using a resilient
bulkhead flange of the FTA series, which helps to cushion the vibrations
propagated between the pipe and the tank lid.
If pipes need to be bent, the radius of curvature must be at least 3 times the
pipe diameter.
Do not use elbow ttings, as these will signicantly increase pressure losses.
- The pressure pipeline of the pump must be flexible and long enough to
include bends with the minimum radius of curvature recommended by the
manufacturer for the specied operating pressure.
- The return pipeline running from the service to the lter must be exible.
Where oil is returned directly to the tank of the hydraulic power unit through
a rigid pipe, it is advisable to use a resilient bulkhead ange of the FTR series,
which helps to cushion the vibrations propagated between the pipe and
the tank lid.
- Anti-vibration devices (resilient mounts or damping rods) must be located
under the feet of the electric motor or the PDM foot brackets, depending on
the mounting position of the motor.
- The lids of hydraulic oil tanks must be sturdy enough to support the load
they carry.
2
MOTOR AND PUMP UNIT MOUNTED
HORIZONTALLY ON MACHINE
- As a matter of good practice, the oil tank and motor-pump unit should be
mounted on a single supporting frame of strength sufcient to support the load.
- If the hydraulic system is tted with a side-mounted lter, the suction pipeline
to the pump must be flexible and long enough to include bends with the
minimum radius of curvature recommended by the manufacturer.
- If the suction filter is not side mounted, the pipeline should be rigid and
installed in conjunction with a compensating coupling.
- The pressure pipeline of the pump must be exible, and long enough to include
bends with the minimum radius of curvature recommended by the manufacturer
for the specied operating pressure.
- The return pipeline running from the service to the lter must be exible.
Where oil is returned directly to the tank of the hydraulic power unit through
a rigid pipe, it is advisable to use a resilient bulkhead ange of the FTR series,
which helps to cushion the vibrations propagated between the pipe
and the tank lid.
- Anti-vibration devices (resilient mounts or damping rods) must be located
under the feet of the electric motor or the PDM foot brackets, depending
on the mounting position of the motor.
FINAL CONSIDERATION
For best results, in any event, the motor-and-pump unit should be incorporated into the hydraulic system in such a way that no one component is rigidly associated
with another, resulting in the propagation of vibration, and consequently noise.
RECOMMENDED TIGHTENING TORQUES FOR MOTOR/PUMP FIXING ON THE BELL-HOUSING
M6
M8
M10
M12
M14
M16
M18
M20
M22
M24
10 N∙m
15 N∙m
50 N∙m
84 N∙m
135 N∙m
205 N∙m
280 N∙m
400 N∙m
530 N∙m
690 N∙m
Note: The above guidelines are indicative only and subordinate to the solutions adopted ultimately by design engineers.
Bell-Housing
59
PCD
40
45.2
50
50.8
56
57.15
60
62.7
63
65
70
71.8
75
80
82.55
85
90
92
72.00
88.90
71.80
80.00
93.00
60.00
63.00
93.00
82.50
76.00
106.40
74.00
98.50
75.00
157.20
100.00
125.00
85.00
80.00
80.00
100.00
82.00
90.00
90.00
84.00
88.90
102.00
100.00
103.20
100.00
100.00
110.00
140.00
115.00
100.00
106.40
130.00
100.00
113.00
95.00
103.00
110.00
106.40
105.00
106.40
146.00
110.00
106.40
112.00
105.00
118.00
112.00
140.00
145.00
2
4
4
2
2
4
4
2
2
4
2
4
4
4
4
2
4
4
2
4
2
4
4
4
4
4
4
4
2
4
2
2
2
2
4
2
4
4
4
4
4
4
2
4
2
2
2
2
2
4
2
2
4
4
191
096
120
052
053
280
057
287
050
234
212
098
147
227
231
042
043
044
051
058
062
168
271
073
289
047
139
024
045
059
061
063
064
065
067
083
087
093
104
169
242
272
060
097
254
260
284
066
134
156
163
164
088
089
Nr. holes Code
Spigot hole
[mm]
Type
GENERAL INFORMATION
Bell-housing with nr. 2 holes
at pump interface, aligned
with through holes at motor
interface.
Valid conguration
for bell-housing up to Ø400
Valid conguration for bell-housing
from Ø450 to Ø660
Bell-housing with nr. 4 holes at
pump interface, aligned with
thread holes at motor interface.
Bell-housing with nr. 2 holes
at pump interface + 22.5°
compared to through holes at
motor interface.
Bell-housing with nr. 4 holes
at pump interface + 22.5°
compared to thread holes at
motor interface.
-”: conguration out of ISO & SAE Standard
Ø Ø Ø Ø
Spigot
hole
Spigot
hole
Spigot
hole
Spigot
hole
PCDPCDPCDPCD
PUMP INTERFACE CODES
-
-
-
ISO3019-2-50-B2
-
-
-
-
SAE A-A 50-2
-
-
-
-
-
-
ISO3019-2-63-B2
-
-
-
-
-
ISO3019-2-63-B4
-
-
-
-
-
ISO3019-2-80-B4
ISO3019-2-80-B2
-
-
-
-
-
-
-
-
-
-
-
-
-
SAE A 82-2
-
-
-
-
-
-
-
-
-
-
-
M8
M8
M8
M8
M10
M5
ø7
M8
M8
M6
ø11
M10
M6
M6
M12
M8
M6
M8
M8
ø8.5
M10
M8
M8
M8
ø7
M10
M10
M8
M8
ø11
M10
M10
M10
M10
M10
M10
M8
ø8.5
M12
M8
M8
M10
M10
M10
M8
M12
M10
M10
M8
M8
ø9
ø9
M8
M10
Ø
Bell-Housing
60
PCD
95
98.4
100
101.6
105
110
112
115
116
120
125
127
130
115.00
127.00
125.00
125.00
125.00
125.00
125.00
190.00
125.00
125.00
140.00
146.00
126.00
120.00
160.00
150.00
161.50
146.00
127.00
146.00
127.00
146.00
175.00
130.00
200.00
135.00
145.00
140.00
140.00
130.00
180.00
160.00
210.00
145.00
150.00
160.00
160.00
160.00
180.00
155.00
160.00
200.00
181.20
200.00
180.00
170.00
161.50
181.20
161.50
165.00
150.00
181.20
165.00
165.00
4
4
4
2
4
4
4
4
4
2
2
2
2
4
4
4
4
2
4
2
4
2
4
4
4
4
4
2
2
4
4
2
2
4
4
4
4
2
2
4
4
4
2
4
4
4
4
2
4
4
4
2
4
4
137
131
128
023
025
031
032
038
041
071
072
075
106
122
141
150
029
070
125
159
224
076
110
154
202
219
273
074
138
264
198
084
094
155
267
026
033
079
082
102
113
114
136
200
215
237
021
080
140
054
068
085
124
135
Nr. holes Code
Spigot hole
[mm]
Type Type
PCD
130
135
140
150
152.4
160
162
165.1
175
177.8
180
200
203.2
205
224
250
275
165.00
160.00
175.40
180.00
180.00
165.00
200.00
165.00
180.00
185.00
228.60
228.60
228.60
217.50
228.60
228.60
190.50
200.00
200.00
200.00
224.00
200.00
230.00
185.00
224.00
230.00
188.00
317.35
317.35
229.00
317.35
200.00
230.00
350.00
216.00
350.00
216.00
216.00
224.00
216.00
215.00
230.00
250.00
250.00
280.00
230.50
254.00
240.00
280.00
280.00
310.00
315.00
355.00
355.00
4
4
4
4
2
4
4
4
2
4
4
2
4
4
2
4
4
4
4
2
2
2
4
4
4
4
4
4
2
4
4
4
2
4
4
2
4
4
4
4
4
4
4
4
2
4
4
4
4
4
4
4
4
4
253
151
220
077
081
157
176
223
232
069
022
090
108
118
166
192
207
027
035
091
092
107
111
152
184
228
263
143
145
201
204
153
185
146
222
203
055
078
112
132
148
226
028
095
117
214
210
133
144
205
238
282
233
281
Nr. holes Code
Spigot hole
[mm]
GENERAL INFORMATION
-”: conguration out of ISO & SAE Standard -”: conguration out of ISO & SAE Standard
PUMP INTERFACE CODES
-
-
-
ISO3019-2-100-B4
ISO3019-2-100-B2
-
-
-
-
-
-
-
-
-
-
-
-
SAE B 101-2
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
ISO3019-2-125-B4
-
-
ISO3019-2-125-B2
-
-
-
-
-
-
-
-
SAE C 127-2
-
-
-
-
-
-
-
-
-
ISO3019-2-140-B4
-
-
ISO3019-2-140-B2
-
-
-
-
-
-
-
SAE D 152-2
SAE D 152 -4
-
ISO3019 - 2 -160 B4
-
-
ISO3019 - 2 -160 B2
-
-
-
-
-
-
SAE E 165 - 4
SAE E 165 - 2
-
-
-
-
SAE F 177 - 4
-
SAE F 177 - 2
-
-
ISO3019 - 2 -180 B4
-
-
-
ISO3019 - 2 -200 B4
-
-
-
-
-
ISO3019 - 2 -224 B4
-
-
ISO3019 - 2 -250 B4
-
-
M8
M10
ø11
M10
M10
ø11
M5
ø15
ø13
M12
M12
M12
M10
M8
M10
M10
M12
M12
M12
M10
M10
M12
M10
M8
M10
M10
M12
M12
M10
M10
M12
M14
M16
M10
ø13
M12
ø13
M12
M16
M10
ø17
M12
M16
M16
ø20
ø18
M12
M16
M14
ø11
M12
M16
M12
M14
M10
M10
M12
M14
M12
M10
M16
ø11
M16
M16
M16
M18
M18
ø17
M20
M20
M8
M16
ø17
M16
M20
M12
M22
M12
M16
ø22
M12
M20
M24
M20
M18
M12
M18
M24
M12
M24
ø13
M16
M16
M12
M22
M22
M20
ø22
M24
M12
M14
M16
M20
ø22
M24
M20
M16
ø18
Ø Ø
Bell-Housing
61
MULTI-COMPONENTS
Technical data
- Base module: Pressure die-cast aluminium alloy
- Pump ange: Aluminium alloy
- Intermediate adapter: Aluminium alloy.
- Screw kit: Steel
- Gaskets: Special paper (Guarnital)
Materials
Modular Bell-Housing Components - IEC electric motor range from size 132 up to size 355
From -30 °C to +80 °C
Temperature
GENERAL INFORMATION
Modular bell-housing components compatible for use with:
- Mineral oils types HH-HL-HM-HR-HV, to ISO 6743/4 standard
- Water based emulsions types HFAE-HFAS, to ISO 6743/4 standard
- Water glycol type HFC, to ISO 6743/4 standard: ask for anodized version
Compatibility with uids
Special Applications
Any applications not covered by the normal indications
contained in this catalogue must be evaluated and approved
by MP Filtri Technical and Sales Department
For temperatures outside this range, contact
MP Filtri Technical and Sales Department
Note
Bell-Housing
92
MULTI-COMPONENTS
BMC200
BMC200
BMC250
BMC250
BMC300
BMC350
BMC350
BMC400
BMC450
BMT300
BMT350
BMT350
BMT400
BMT450
BMT550
BMT550
BMT660
BAD800
127-2
(C)
127-2
(C)
Bell-Housing
size
Bell-Housing
size
50-2
(A-A)
50-2
(A-A)
82-2
(A)
82-2
(A)
101-2
(B)
101-2
(B)
Flange SAE J 744
Flange SAE J 744
152-2
(D)
152-2
(D)
165-2
(E)
165-2
(E)
IEC Motors
size
IEC Motors
size
101-4
(B)
101-4
(B)
127-4
(D)
127-4
(D)
152-4
(D)
152-4
(D)
165-4
(E)
165-4
(E)
BMC200
BMC200
BMC250
BMC250
BMC300
BMC350
BMC350
BMC400
BMC450
BMT300
BMT350
BMT350
BMT400
BMT450
BMT550
BMT550
BMT660
BAD800
100
B2-B4
100
B2-B4
Bell-Housing
size
Bell-Housing
size
50
B2-B4
50
B2-B4
63
B2-B4
63
B2-B4
80
B2-B4
80
B2-B4
Flange ISO 3019-2
Flange ISO 3019-2
125
B2-B4
125
B2-B4
160
B2-B4
160
B2-B4
IEC Motors
size
IEC Motors
size
200
B2-B4
200
B2-B4
GENERAL INFORMATION
BMC
BMT
IEC 80 Ø200 - Ø19x40
IEC 90
Ø200 - Ø24x50
IEC 100
Ø250 - Ø28x60
IEC 112
Ø250 - Ø28x60
IEC 132
Ø300 - Ø38x80
IEC 160
Ø350 - Ø42x110
IEC 180
Ø350 - Ø48x110
IEC 200
Ø400 - Ø55x110
IEC 225
Ø450 - Ø60x140
IEC 132
Ø300 - Ø38x80
IEC 160
Ø350 - Ø42x110
IEC 180
Ø350 - Ø48x110
IEC 200
Ø400 - Ø55x110
IEC 225
Ø450 - Ø60x140
IEC 250
Ø550 - Ø65x140
IEC 280
Ø550 - Ø75x140
IEC 315
Ø660 - Ø80x170
IEC 355
Ø800 - Ø95x210
IEC 80
Ø200 - Ø19x40
IEC 90
Ø200 - Ø24x50
IEC 100
Ø250 - Ø28x60
IEC 112
Ø250 - Ø28x60
IEC 132
Ø300 - Ø38x80
IEC 160
Ø350 - Ø42x110
IEC 180
Ø350 - Ø48x110
IEC 200
Ø400 - Ø55x110
IEC 225
Ø450 - Ø60x140
IEC 132
Ø300 - Ø38x80
IEC 160
Ø350 - Ø42x110
IEC 180
Ø350 - Ø48x110
IEC 200
Ø400 - Ø55x110
IEC 225
Ø450 - Ø60x140
IEC 250
Ø550 - Ø65x140
IEC 280
Ø550 - Ø75x140
IEC 315
Ø660 - Ø80x170
IEC 355
Ø800 - Ø95x210
Bell-Housing
93
Designation & Ordering code
Motor base series and size
Intermediate adapter series and size
BMC200A1001
AD60465
BMT300A0805 BMT550A21567
BMT400A1106 BAD800A2707
BMC200A1251
AD50385
BMT350A1105 BMT660A25067
BMT450A1406
Conguration example:
Conguration example:
BMC300A1551 BMC400A2016
BMC300A1555 BMC450A2507
BMC300A1705
BMC350A1945
BMC350A1946
BMC250A1141
AD60466
AD50467
BMC200A1001
AD60465
DI
AN
BMC250A1361
AD50386
AD60467
Options
Options
DI
AN
AN
Drain hole + inspection hole
Black anodized nish
Black anodized nish
BMC
Pump interface codes
070
See page 60
Pxx
Pxx
SA
Customer specication
Customer specication
Clearance holes at motor interface
Pump ange series and size
Mounting kit code series and size
FR1023
KVG1
FR1025
KVG5
Conguration example:
FP5026 FP6032 FP7052
FP5032 FP6045 FP7066
FP5035 FP6058 FP7069
FP5063 FP6086
FP5045 FP6070 FP7086
FP60101
FP5056 FP6082 FP70111
FP5091
FP60110
FR1033
FR1040
KVG6
FP5026 AN070
FR1035
FR1079
KVG7
Options
FR
DP
Holes rotated through 45° in relation to standard position
Double set of hole
Pxx
AN
Customer specication
Black anodized nish
See page 111
97
Options
MULTI-COMPONENTS
1
2
3
Bell-Housing
94
Ø3
Ø2
Ø1
Ø5
Ø6
Ø3
Ø2
Ø1
Ø5
Ø6
BMC / FLANGE FR1
Inspection Hole
Plastic threaded plug mounted
(protection according
to DIN EN 292 part 2)
“Safety of machines”
Drain hole
(on request)
4 Bolt Version 2 Bolt Version
Nr.4xP
Nr.4xF
Nr.4xM8
Motor
size
BMC200A1001
BMC200A1251
BMC250A1141
BMC250A1361
BMC300A1551
FR1023***
FR1025***
FR1033***
FR1035***
FR1040***
FR1079***
H1
H1
Motor base
code
Ø1
2 Bolt 4 Bolt
Ø2 Ø3 Ø5
Dimensions [mm]
Mounting
kit
Available pump interface
H2 F P
Weight
[kg]
Weight
[kg]
130
130
180
180
230
D042 - S061 - S063 -S083 - S023 - S070 -S071 - S082 - S075
S080 - S082
S023 - S070 - S071 - S072 -S074 S080 -S082
S060 - S063 -S065
-
-
S024 - S025 - S125 - S154
S021 - S026 - S068 -S069
S021 - S026 - S027
-
S098 - S227
S031
165
165
215
215
265
200
200
250
250
300
135
135
186
186
235
100
125
114
138
155
23
25
33
35
40
79
KVG1
18
18
19
19
23
M10
M10
M12
M12
M12
11
11
14
14
14
0.75
0.95
1.60
1.60
3.30
0.25
0.30
0.80
0.90
1.10
1.30
80
90
100-112
132
19x40
24x50
28x60
38x80
IEC - Electric motors
Pump ange
code
Motor size
Shaft end [Ø x L]
On request
See page 111
H3 Ø6
60
75
80
100
95
3/4”
3/4”
3/4”
3/4”
3/4”
Pump ange code to be complete with available pump interface
Example: FR1023S024
The codes on the chart must be used for dimensionalchecking only; the ordering codes for all components
are available on the on-line software “Power Transmission Software” on the web sitewww.mpltri.com
MULTI-COMPONENTS2
1
3
Bell-Housing
95
Ø3
Ø2
Ø1
Ø5
Ø6
Ø170
Ø170
Ø170
Ø190
Ø190
Ø3
Ø2
Ø1
Ø5
Ø6
Ø170
Ø170
Ø170
Ø190
Ø190
Inspection Hole
Plastic threaded plug mounted
(protection according
to DIN EN 292 part 2)
“Safety of machines”
Drain hole
(on request)
4 Bolt Version 2 Bolt Version
Nr.4xP
Nr.4xF
Nr.4xM14
Motor
size
BMC300A1555
BMC300A1705
BMC350A1785
BMC350A1945
FP5026***
FP5032***
FP5035***
FP5045***
FP5056***
FP5063***
FP5091***
H1
H1
Motor base
code
Ø1
2 Bolt 4 Bolt
Ø2 Ø3 Ø5
Dimensions [mm]
Mounting
kit
Available pump interface
H2 PF
Weight
[kg]
Weight
[kg]
230
230
250
250
S023 - D042 - S063 - S070 - S072 S075
-
S023 - D042 - S063 - S070 - S072 - S075 - S060 - S072 - S074 - S075 - S106
S060 - S070 - S071 - S072 - S074 - S075 - S106
S072
S070 - S079 - S138
-
S024 - S024 -S033 - S125 - S154
S024 - S031 - S096 - S125
S021 - S024 - S025 - S026 - S031 - S059 - S068 - S083 - S097 - S125 - S141
S021 - S024 - S025 - S026 - S068 - S125 -S141
S021 - S026
S021 - S025 - S068 -S141
S025 - S031 - S033 - S113 - S267
265
265
300
300
300
300
350
350
235
235
254
254
155
170
178
194
26
32
35
45
56
63
91
KVG5
23
23
31
31
14
14
18
18
M12
M12
M16
M16
3.3
3.6
4.4
4.9
1.0
1.1
0.9
0.9
1.6
1.7
2.2
132
160
180
38x80
42x110
48x110
IEC - Electric motors
Pump ange
code
Motor size
Shaft end [Ø x L]
On request
See page
111
H3 Ø6
95
110
100
115
3/4”
3/4”
1”
1”
Pump ange code to be complete with available pump interface
Example: FP5026S023
BMC / FLANGE FP5
ø10
MULTI-COMPONENTS 2
1
3
The codes on the chart must be used for dimensionalchecking only; the ordering codes for all components
are available on the on-line software “Power Transmission Software” on the web sitewww.mpltri.com
Bell-Housing
96
Inspection Hole
Plastic threaded plug mounted
(protection according
to DIN EN 292 part 2)
“Safety of machines”
Drain hole
(on request)
4 Bolt Version 2 Bolt Version
Nr.4xP
Nr.4xF
Nr.4xM14
Motor
size
BMC350A1786
BMC350A1946
BMC400A2016
FP6032***
FP6045***
FP6058***
FP6070***
FP6082***
FP6086***
FP6101***
FP6110***
H1
H1
Motor base
code
Ø1
2 Bolt 4 Bolt
Ø2 Ø3 Ø5
Dimensions [mm]
Mounting
kit
Available pump interface
H2 PF
Weight
[kg]
Weight
[kg]
250
250
300
S081 - S082
S070 - S075 - S080 - S081 - S082
S079 - S080 - S081 - S082
S080
S080 - S081
S090 - S092 - S166 - S091
-
S080
S021 - S035
S021 -S025 - S026 -S027 - S069 - S077 -S125 - S198 - S207 - S215 - S253
S025 - S026 -S027 - S038 - S077 - S078 - S207 - S215 - S237
-
S038 - S141 - 198 - 215
S021 - S026 - S027 - S077 - S078 - S114 - S132 - 198 - S200
S027 - S035 - S113 -S132 - S148 - S176 - S228
S111
300
300
350
350
350
400
254
254
305
178
194
201
32
45
58
70
82
86
101
110
KVG6
31
31
31
18
18
18
M16
M16
M16
4.4
1.9
6.9
1.8
2.1
2.4
3.0
3.3
3.4
4.2
5.5
160
180
200
42x110
48x110
55x110
IEC - Electric motors
Pump ange
code
Motor size
Shaft end [Ø x L]
On request
See page
111
H3 Ø6
100
115
125
1”
1”
1 1/2”
Pump ange code to be complete with available pump interface
Example: FP6032S021
BMC / FLANGE FP6
Ø218
Ø218
Ø218
Ø218
Ø240
Ø240
Ø3
Ø2
Ø1
Ø10
Ø5
Ø6
Ø218
Ø218
Ø218
Ø218
Ø240
Ø240
Ø3
Ø2
Ø1
Ø10
Ø5
Ø6
MULTI-COMPONENTS2
1
3
The codes on the chart must be used for dimensionalchecking only; the ordering codes for all components
are available on the on-line software “Power Transmission Software” on the web sitewww.mpltri.com
Bell-Housing
97
Ø218
Ø218
Ø218
Ø240
Ø240
Ø3
Ø2
Ø1
Ø10
Ø5
Ø6
Inspection Hole
Plastic threaded plug mounted
(protection according
to DIN EN 292 part 2)
“Safety of machines”
Drain hole
(on request)
4 Bolt Version 2 Bolt Version
Nr.8xF
Nr.4xM14
Motor
size
BMC450A2506
FP6032***
FP6045***
FP6058***
FP6070***
FP6082***
FP6086***
FP6101***
FP6110***
H1
H1
Motor base
code
Ø1
2 Bolt 4 Bolt
Ø2 Ø3 Ø5
Dimensions [mm]
Mounting
kit
Available pump interface
H2 PF
Weight
[kg]
Weight
[kg]
350
S081 - S082
S070 - S075 - S080 - S081 - S082
S079 - S080 - S081 - S082
S080
S080 - S081
S090 - S092 - S166 - S091
-
S080
S021 - S035
S021 -S025 - S026 -S027 - S069 - S077 -S125 - S198 - S207 - S215 - S253
S025 - S026 -S027 - S038 - S077 - S078 - S207 - S215 - S237
-
S038 - S141 - 198 - 215
S021 - S026 - S027 - S077 - S078 - S114 - S132 - 198 - S200
S027 - S035 - S113 -S132 - S148 - S176 - S228
S111
400 450 350 250
32
45
58
70
82
86
101
110
31 -M16 6.9
1.8
2.1
2.4
3.0
3.3
3.4
4.2
5.5
225 60x140
IEC - Electric motors
Pump ange
code
Motor size
Shaft end [Ø x L]
On request
H3 Ø6
175 1 1/2”
Pump ange code to be complete with available pump interface
Example: FP6032S021
BMC / FLANGE FP6
Ø218
Ø218
Ø218
Ø240
Ø240
Ø3
Ø2
Ø1
Ø10
Ø5
Ø6
KVG6
See page
111
MULTI-COMPONENTS 2
1
3
The codes on the chart must be used for dimensionalchecking only; the ordering codes for all components
are available on the on-line software “Power Transmission Software” on the web sitewww.mpltri.com
Bell-Housing
98
Ø3
Ø2
Ø1
Ø5
Ø6
Ø258
Ø288
Ø288
Ø258
Ø258
Ø3
Ø2
Ø1
Ø5
Ø6
Ø258
Ø288
Ø288
Ø258
Ø258
Inspection Hole
Plastic threaded plug mounted
(protection according
to DIN EN 292 part 2)
“Safety of machines”
Drain hole
(on request)
4 Bolt Version 2 Bolt Version
Nr.8xF
Nr.4xM20
Motor
size
BMC450A2507
FP7052***
FP7066***
FP7069***
FP7086***
FP7111***
H1
H1
Motor base
code
Ø1
2 Bolt 4 Bolt
Ø2 Ø3 Ø5
Dimensions [mm]
Mounting
kit
Available pump interface
H2 PF
Weight
[kg]
Weight
[kg]
350
-
S090 - S092 - S166
-
S091 - S092 - S117 - S166
S091 - S092 - S117 - S145
S028 - S108 - S112 - S133 - S192
-
S108 - S143 - S148 - S192 - S201 - S204 - S281 -S282
S022 - S027 - S028 - S108 - S112 - S184 - S192 - S201 - S228 - S300
S028 - S108 - S112 - S133 - S184
400 450 350 250
52
66
69
86
111
31 -M16 6.9
4.4
4.8
4.9
5.2
6.3
225 60x140
IEC - Electric motors
Pump ange
code
Motor size
Shaft end [Ø x L]
On request
H3 Ø6
175 1 1/2”
Pump ange code to be complete with available pump interface
Example: FP7052S028
BMC / FLANGE FP7
KVG7
See page
111
ø10
MULTI-COMPONENTS2
1
3
The codes on the chart must be used for dimensionalchecking only; the ordering codes for all components
are available on the on-line software “Power Transmission Software” on the web sitewww.mpltri.com
Bell-Housing
99
Ø1
Ø2
Ø2
BMT300
Flange
Inspection Hole
Plastic threaded plug mounted
(protection according to DIN EN 292 part 2)
“Safety of machines”
Drain hole
(on request)
4 Bolt Version 2 Bolt Version
Nr.4xM12
Nr.4xø14
Nr.4xP Nr.4xP
Nr.8xØ15
Motor
size
Motor base
interface
Pump ange
interface
FP5026***
FP5032***
FP5035***
FP5045***
FP5056***
FP5063***
FP5091***
FP6032***
FP6045***
FP6058***
FP6070***
FP6082***
FP6086***
FP6101***
FP6110***
FP7052***
FP7066***
FP7069***
FP7086***
FP7111***
H1 Ø1 Ø2 P 2 Bolt 4 Bolt
Mounting
kit
Available pump interface Weight
[kg]
S023 - D042 - S063 - S070 - S072 S075
-
S023 - D042 - S063 - S070 - S072 - S075 - S060 - S072 - S074 - S075 - S106
S060 - S070 - S071 - S072 - S074 - S075 - S106
S072
S070 - S079 - S138
-
S081 - S082
S070 - S075 - S080 - S081 - S082
S079 - S080 - S081 - S082
S080
S080 - S081
S090 - S092 - S166 - S091
-
S080
-
S090 - S092 - S166
-
S091 - S092 - S117 - S166
S091 - S092 - S117 - S145
S024 - S024 -S033 - S125 - S154
S024 - S031 - S096 - S125
S021 - S024 - S025 - S026 - S031 - S059 - S068 - S083 - S097 - S125 - S141
S021 - S024 - S025 - S026 - S068 - S125 -S141
S021 - S026
S021 - S025 - S068 -S141
S025 - S031 - S033 - S113 - S267
S021 - S035
S021 -S025 - S026 -S027 - S069 - S077 -S125 - S198 - S207 - S215 - S253
S025 - S026 -S027 - S038 - S077 - S078 - S207 - S215 - S237
-
S038 - S141 - 198 - 215
S021 - S026 - S027 - S077 - S078 - S114 - S132 - 198 - S200
S027 - S035 - S113 -S132 - S148 - S176 - S228
S111
S028 - S108 - S112 - S133 - S192
-
S108 - S143 - S148 - S192 - S201 - S204 - S281 -S282
S022 - S027 - S028 - S108 - S112 - S184 - S192 - S201 - S228 - S300
S028 - S108 - S112 - S133 - S184
170 15
32
45
58
70
82
86
101
110
190
17
52
66
69
86
111
288 258 22
KVG5
KVG6
KVG7
BMT300A0805
Motor base
code
Weight
[kg]
1.95
1
1.1
0.9
0.9
1.6
1.7
2.2
1.8
2.1
2.4
3.0
3.3
3.4
4.2
5.5
4.4
4.8
4.9
5.2
6.3
Pump ange
code
See page
111
See page
111
See page
111
Pump ange code to be complete with available pump interface
Example: FP6032S021
Ø10
Ø190
Ø234
Ø300
Ø265
Ø230
Ø166
218240
1
3
MULTI-COMPONENTS 3
26
32
35
45
56
63
91
The codes on the chart must be used for dimensionalchecking only; the ordering codes for all components
are available on the on-line software “Power Transmission Software” on the web sitewww.mpltri.com
Bell-Housing
100
BMT300
Flange interface Motor base interface
AD50385
Code Weight [kg]
1.00
AD50386
Code Weight [kg]
1.25
AD50467
Code Weight [kg]
1.90
Nr.4xM14
Nr.4xM16
Nr.4xM20
Nr.4xM14
Nr.4xM14
Nr.4xM14
Ø170
Ø218
Ø258
Ø166
Ø166
Ø166
Ø190
Ø240
Ø190
Ø190
Ø190
Ø288
2
MULTI-COMPONENTS 3
Bell-Housing
101
BMT350
Inspection Hole
Plastic threaded plug mounted
(protection according to DIN EN 292 part 2)
“Safety of machines”
Drain hole
(on request)
Nr.4xM16
Nr.4xØ18
Nr.8xØ15
Motor
size
Motor base
interface
FP5026***
FP5032***
FP5035***
FP5045***
FP5056***
FP5063***
FP5091***
FP6032***
FP6045***
FP6058***
FP6070***
FP6082***
FP6086***
FP6101***
FP6110***
FP7052***
FP7066***
FP7069***
FP7086***
FP7111***
H1 Ø1 Ø2 P 2 Bolt 4 Bolt
Mounting
kit
Available pump interface Weight
[kg]
S023 - D042 - S063 - S070 - S072 S075
-
S023 - D042 - S063 - S070 - S072 - S075 - S060 - S072 - S074 - S075 - S106
S060 - S070 - S071 - S072 - S074 - S075 - S106
S072
S070 - S079 - S138
-
S081 - S082
S070 - S075 - S080 - S081 - S082
S079 - S080 - S081 - S082
S080
S080 - S081
S090 - S092 - S166 - S091
-
S080
-
S090 - S092 - S166
-
S091 - S092 - S117 - S166
S091 - S092 - S117 - S145
S024 - S024 -S033 - S125 - S154
S024 - S031 - S096 - S125
S021 - S024 - S025 - S026 - S031 - S059 - S068 - S083 - S097 - S125 - S141
S021 - S024 - S025 - S026 - S068 - S125 -S141
S021 - S026
S021 - S025 - S068 -S141
S025 - S031 - S033 - S113 - S267
S021 - S035
S021 -S025 - S026 -S027 - S069 - S077 -S125 - S198 - S207 - S215 - S253
S025 - S026 -S027 - S038 - S077 - S078 - S207 - S215 - S237
-
S038 - S141 - 198 - 215
S021 - S026 - S027 - S077 - S078 - S114 - S132 - 198 - S200
S027 - S035 - S113 -S132 - S148 - S176 - S228
S111
S028 - S108 - S112 - S133 - S192
-
S108 - S143 - S148 - S192 - S201 - S204 - S281 -S282
S022 - S027 - S028 - S108 - S112 - S184 - S192 - S201 - S228 - S300
S028 - S108 - S112 - S133 - S184
15
32
45
58
70
82
86
101
110
17
52
66
69
86
111
288 258 22
1
1.1
0.9
0.9
1.6
1.7
2.2
1.8
2.1
2.4
3.0
3.3
3.4
4.2
5.5
4.4
4.8
4.9
5.2
6.3
Pump ange
code
Pump ange code to be complete with available pump interface
Example: FP6032S021
Ø1
Ø2
Ø2
Flange
4 Bolt Version 2 Bolt Version
Nr.4xP Nr.4xP
Pump ange
interface
BMT350A1105
Motor base
code
Weight
[kg]
3.10
KVG5
KVG6
KVG7
See page
111
See page
111
See page
111
Ø10
Ø190
Ø260
Ø166
Ø350
Ø300
Ø250
170190
218240
MULTI-COMPONENTS 3
1
3
26
32
35
45
56
63
91
The codes on the chart must be used for dimensionalchecking only; the ordering codes for all components
are available on the on-line software “Power Transmission Software” on the web sitewww.mpltri.com
Bell-Housing
102
BMT350
Flange interface Motor base interface
AD50385
Code Weight [kg]
1.00
AD50386
Code Weight [kg]
1.25
AD50467
Code Weight [kg]
1.90
Nr.4xM14
Nr.4xM16
Nr.4xM20
Nr.4xM14
Nr.4xM14
Nr.4xM14
Ø170
Ø166
Ø190
Ø190
Ø218
Ø166
Ø240
Ø190
Ø258
Ø166
Ø190
Ø288
MULTI-COMPONENTS 3
2
Bell-Housing
103
BMT400
Inspection Hole
Plastic threaded plug mounted
(protection according to DIN EN 292 part 2)
“Safety of machines”
Drain hole
(on request)
Nr.4xM16
Nr.4xØ18
Nr.8xØ15
Motor
size
Motor base
interface
FP5026***
FP5032***
FP5035***
FP5045***
FP5056***
FP5063***
FP5091***
FP6032***
FP6045***
FP6058***
FP6070***
FP6082***
FP6086***
FP6101***
FP6110***
FP7052***
FP7066***
FP7069***
FP7086***
FP7111***
H1 Ø1 Ø2 P 2 Bolt 4 Bolt
Mounting
kit
Available pump interface Weight
[kg]
S023 - D042 - S063 - S070 - S072 S075
-
S023 - D042 - S063 - S070 - S072 - S075 - S060 - S072 - S074 - S075 - S106
S060 - S070 - S071 - S072 - S074 - S075 - S106
S072
S070 - S079 - S138
-
S081 - S082
S070 - S075 - S080 - S081 - S082
S079 - S080 - S081 - S082
S080
S080 - S081
S090 - S092 - S166 - S091
-
S080
-
S090 - S092 - S166
-
S091 - S092 - S117 - S166
S091 - S092 - S117 - S145
S024 - S024 -S033 - S125 - S154
S024 - S031 - S096 - S125
S021 - S024 - S025 - S026 - S031 - S059 - S068 - S083 - S097 - S125 - S141
S021 - S024 - S025 - S026 - S068 - S125 -S141
S021 - S026
S021 - S025 - S068 -S141
S025 - S031 - S033 - S113 - S267
S021 - S035
S021 -S025 - S026 -S027 - S069 - S077 -S125 - S198 - S207 - S215 - S253
S025 - S026 -S027 - S038 - S077 - S078 - S207 - S215 - S237
-
S038 - S141 - 198 - 215
S021 - S026 - S027 - S077 - S078 - S114 - S132 - 198 - S200
S027 - S035 - S113 -S132 - S148 - S176 - S228
S111
S028 - S108 - S112 - S133 - S192
-
S108 - S143 - S148 - S192 - S201 - S204 - S281 -S282
S022 - S027 - S028 - S108 - S112 - S184 - S192 - S201 - S228 - S300
S028 - S108 - S112 - S133 - S184
15
32
45
58
70
82
86
101
110
17
52
66
69
86
111
288 258 22
1
1.1
0.9
0.9
1.6
1.7
2.2
1.8
2.1
2.4
3.0
3.3
3.4
4.2
5.5
4.4
4.8
4.9
5.2
6.3
Pump ange
code
Pump ange code to be complete with available pump interface
Example: FP6032S021
Ø1
Ø2
Ø2
Flange
4 Bolt Version 2 Bolt Version
Nr.4xP Nr.4xP
Pump ange
interface
BMT400A1106
Motor base
code
Weight
[kg]
4.90
KVG5
KVG6
KVG7
See page
111
See page
111
See page
111
Ø10
Ø240
Ø300
Ø208
Ø400
Ø350
Ø300
1 1/2”
170190
218240
1
3
MULTI-COMPONENTS 3
26
32
35
45
56
63
91
The codes on the chart must be used for dimensionalchecking only; the ordering codes for all components
are available on the on-line software “Power Transmission Software” on the web sitewww.mpltri.com
Bell-Housing
104
BMT400
Flange interface Motor base interface
AD60465
Code Weight [kg]
1.30
AD60466
Code Weight [kg]
1.60
AD60467
Code Weight [kg]
2.50
Nr.4xM14
Nr.4xM16
Nr.4xM20
Nr.4xM16
Nr.4xM16
Nr.4xM16
Ø170
Ø218
Ø258
Ø208
Ø208
Ø208
Ø190
Ø240
Ø288
Ø240
Ø240
Ø240
2
MULTI-COMPONENTS 3
Bell-Housing
105
BMT450
Inspection Hole
Plastic threaded plug mounted
(protection according to DIN EN 292 part 2)
“Safety of machines”
Drain hole
(on request)
Nr.8xM16
Nr.8xØ17.5
Motor
size
FP5026***
FP5032***
FP5035***
FP5045***
FP5056***
FP5063***
FP5091***
FP6032***
FP6045***
FP6058***
FP6070***
FP6082***
FP6086***
FP6101***
FP6110***
FP7052***
FP7066***
FP7069***
FP7086***
FP7111***
H1 Ø1 Ø2 P 2 Bolt 4 Bolt
Mounting
kit
Available pump interface Weight
[kg]
S023 - D042 - S063 - S070 - S072 S075
-
S023 - D042 - S063 - S070 - S072 - S075 - S060 - S072 - S074 - S075 - S106
S060 - S070 - S071 - S072 - S074 - S075 - S106
S072
S070 - S079 - S138
-
S081 - S082
S070 - S075 - S080 - S081 - S082
S079 - S080 - S081 - S082
S080
S080 - S081
S090 - S092 - S166 - S091
-
S080
-
S090 - S092 - S166
-
S091 - S092 - S117 - S166
S091 - S092 - S117 - S145
S024 - S024 -S033 - S125 - S154
S024 - S031 - S096 - S125
S021 - S024 - S025 - S026 - S031 - S059 - S068 - S083 - S097 - S125 - S141
S021 - S024 - S025 - S026 - S068 - S125 -S141
S021 - S026
S021 - S025 - S068 -S141
S025 - S031 - S033 - S113 - S267
S021 - S035
S021 -S025 - S026 -S027 - S069 - S077 -S125 - S198 - S207 - S215 - S253
S025 - S026 -S027 - S038 - S077 - S078 - S207 - S215 - S237
-
S038 - S141 - 198 - 215
S021 - S026 - S027 - S077 - S078 - S114 - S132 - 198 - S200
S027 - S035 - S113 -S132 - S148 - S176 - S228
S111
S028 - S108 - S112 - S133 - S192
-
S108 - S143 - S148 - S192 - S201 - S204 - S281 -S282
S022 - S027 - S028 - S108 - S112 - S184 - S192 - S201 - S228 - S300
S028 - S108 - S112 - S133 - S184
15
32
45
58
70
82
86
101
110
17
52
66
69
86
111
288 258 22
1.0
1.1
0.9
0.9
1.6
1.7
2.2
1.8
2.1
2.4
3.0
3.3
3.4
4.2
5.5
4.4
4.8
4.9
5.2
6.3
Pump ange
code
Pump ange code to be complete with available pump interface
Example: FP6032S021
Ø1
Ø2
Ø2
Flange
4 Bolt Version 2 Bolt Version
Nr.4xP Nr.4xP
Pump ange
interface
BMT450A1406
Motor base
code
Weight
[kg]
5.00
KVG5
KVG6
KVG7
See page
111
See page
111
See page
111
Ø10
Ø240
Ø350
1 1/4”
Ø208
Ø450
Ø400
Ø350
170190
218240
1
3
MULTI-COMPONENTS 3
26
32
35
45
56
63
91
The codes on the chart must be used for dimensionalchecking only; the ordering codes for all components
are available on the on-line software “Power Transmission Software” on the web sitewww.mpltri.com
Bell-Housing
106
BMT450
Flange interface Motor base interface
AD60465
Code Weight [kg]
1.30
AD60466
Code Weight [kg]
1.60
AD60467
Code Weight [kg]
2.50
Nr.4xM14
Nr.4xM16
Nr.4xM20
Nr.4xM16
Nr.4xM16
Nr.4xM16
Ø170
Ø208
Ø190
Ø240
Ø218
Ø208
Ø240
Ø240
Ø258
Ø208
Ø288
Ø240
2
MULTI-COMPONENTS 3
Bell-Housing
107
BMT550
Inspection Hole
Plastic threaded plug mounted
(protection according
to DIN EN 292 part 2)
“Safety of machines”
Drain hole
(on request)
Nr.4xM20
Nr.4xM16
Nr.16xM16
Motor
size
FP6032***
FP6045***
FP6058***
FP6070***
FP6082***
FP6086***
FP6101***
FP6110***
FP7052***
FP7066***
FP7069***
FP7086***
FP7111***
H1 Ø1 Ø2 P 2 Bolt 4 Bolt
Mounting
kit
Available pump interface Weight
[kg]
S081 - S082
S070 - S075 - S080 - S081 - S082
S079 - S080 - S081 - S082
S080
S080 - S081
S090 - S092 - S166 - S091
-
S080
-
S090 - S092 - S166
-
S091 - S092 - S117 - S166
S091 - S092 - S117 - S145
S021 - S035
S021 -S025 - S026 -S027 - S069 - S077 -S125 - S198 - S207 - S215 - S253
S025 - S026 -S027 - S038 - S077 - S078 - S207 - S215 - S237
-
S038 - S141 - 198 - 215
S021 - S026 - S027 - S077 - S078 - S114 - S132 - 198 - S200
S027 - S035 - S113 -S132 - S148 - S176 - S228
S111
S028 - S108 - S112 - S133 - S192
-
S108 - S143 - S148 - S192 - S201 - S204 - S281 -S282
S022 - S027 - S028 - S108 - S112 - S184 - S192 - S201 - S228 - S300
S028 - S108 - S112 - S133 - S184
32
45
58
70
82
86
101
110
17
52
66
69
86
111
288 258 22
1.8
2.1
2.4
3.0
3.3
3.4
4.2
5.5
4.4
4.8
4.9
5.2
6.3
Pump ange
code
Pump ange code to be complete with available pump interface
Example: FP6032S021
Ø1
Ø2
Ø2
Flange
4 Bolt Version 2 Bolt Version
Nr.4xP Nr.4xP
Pump ange
interface
BMT550A21567
Motor base
code
Weight
[kg]
8.80
KVG6
KVG7
See page
111
See page
111
Ø258
Ø218
Ø550
Ø500
Ø450
Ø240
Ø288
Ø450
Ø10
218240
1
3
MULTI-COMPONENTS 2
1 1/2”
The codes on the chart must be used for dimensionalchecking only; the ordering codes for all components
are available on the on-line software “Power Transmission Software” on the web sitewww.mpltri.com
Bell-Housing
108
BMT660
Inspection Hole
Plastic threaded plug mounted
(protection according
to DIN EN 292 part 2)
“Safety of machines”
Drain hole
(on request)
Nr.4xM20
Nr.4xM16
Nr.16xM20
Motor
size
FP6032***
FP6045***
FP6058***
FP6070***
FP6082***
FP6086***
FP6101***
FP6110***
FP7052***
FP7066***
FP7069***
FP7086***
FP7111***
H1 Ø1 Ø2 P 2 Bolt 4 Bolt
Mounting
kit
Available pump interface Weight
[kg]
S081 - S082
S070 - S075 - S080 - S081 - S082
S079 - S080 - S081 - S082
S080
S080 - S081
S090 - S092 - S166 - S091
-
S080
-
S090 - S092 - S166
-
S091 - S092 - S117 - S166
S091 - S092 - S117 - S145
S021 - S035
S021 -S025 - S026 -S027 - S069 - S077 -S125 - S198 - S207 - S215 - S253
S025 - S026 -S027 - S038 - S077 - S078 - S207 - S215 - S237
-
S038 - S141 - 198 - 215
S021 - S026 - S027 - S077 - S078 - S114 - S132 - 198 - S200
S027 - S035 - S113 -S132 - S148 - S176 - S228
S111
S028 - S108 - S112 - S133 - S192
-
S108 - S143 - S148 - S192 - S201 - S204 - S281 -S282
S022 - S027 - S028 - S108 - S112 - S184 - S192 - S201 - S228 - S300
S028 - S108 - S112 - S133 - S184
32
45
58
70
82
86
101
110
17
52
66
69
86
111
288 258 22
1.8
2.1
2.4
3.0
3.3
3.4
4.2
5.5
4.4
4.8
4.9
5.2
6.3
Pump ange
code
Pump ange code to be complete with available pump interface
Example: FP6032S021
Ø1
Ø2
Ø2
Flange
4 Bolt Version 2 Bolt Version
Nr.4xP Nr.4xP
Pump ange
interface
BMT660A25067
Motor base
code
Weight
[kg]
12.00
KVG6
KVG7
See page
111
See page
111
Ø258
Ø218
Ø660
Ø600
Ø550
Ø240
Ø288
Ø10
Ø550
218240
1
3
MULTI-COMPONENTS 2
1 1/2”
The codes on the chart must be used for dimensionalchecking only; the ordering codes for all components
are available on the on-line software “Power Transmission Software” on the web sitewww.mpltri.com
Bell-Housing
109
Inspection Hole
Plastic threaded plug mounted
(protection according
to DIN EN 292 part 2)
“Safety of machines”
Drain hole
(on request)
Nr.4xM20
Nr.16xM20
Motor
size
FP7052***
FP7066***
FP7069***
FP7086***
FP7111***
H1 Ø1 Ø2 P 2 Bolt 4 Bolt
Mounting
kit
Available pump interface Weight
[kg]
-
S090 - S092 - S166
-
S091 - S092 - S117 - S166 -
S091 - S092 - S117 - S145
S028 - S108 - S112 - S133 - S192
-
S108 - S143 - S148 - S192 - S201 - S204 - S281 -S282
S022 - S027 - S028 - S108 - S112 - S184 - S192 - S201 - S228 - S300
S028 - S108 - S112 - S133 - S184
52
66
69
86
111
288 258 22
4.4
4.8
4.9
5.2
6.3
Pump ange
code
Pump ange code to be complete with available pump interface
Example: FP7052S028
Flange
4 Bolt Version 2 Bolt Version
Nr.4xØ22 Nr.4xØ22
Pump ange
interface
BAD800A2707
Motor base
code
Weight
[kg]
31.00
KVG7
See page
111
Ø258
Ø800
Ø740
Ø680
Ø288
Ø680
Ø10
Ø258 Ø258
Ø288
1
3
BAD800MULTI-COMPONENTS 2
1 1/2”
The codes on the chart must be used for dimensionalchecking only; the ordering codes for all components
are available on the on-line software “Power Transmission Software” on the web sitewww.mpltri.com
Bell-Housing
110
MOUNTING KIT
Ø85.5
Ø105
Ø132
Ø170
Ø189.5
Ø180
Ø218
Ø239
Ø205
Ø258
Ø287
KVG1
KVG5
KVG6
KVG7
Q.ty
Q.ty
Q.ty
Q.ty
Material
Material
Material
Material
Torque
Torque
Torque
Torque
1
4
4
1
4
4
1
4
4
1
4
Paper
Steel
Steel
Paper
Steel
Steel
Paper
Steel
Steel
Paper
Steel
-
200 Nm
-
-
130 Nm
-
-
90 Nm
-
-
15 Nm
Item
Item
Item
Item
Description
Description
Description
Description
Components
Components
Components
Components
1
2
3
1
2
3
1
2
3
1
2
1
1
1
1
2
2
2
2
3
3
3
Gasket for auxiliary ange FP7 / AD7
Screw T.C.E.I. M20x50 UNI-5931 8.8
Washer Schnorr 20
Gasket for auxiliary ange FP6 / AD6
Screw T.C.E.I. M16x35 UNI-5931 8.8
Washer Schnorr 16
Gasket for auxiliary ange FP5 / AD5
Screw T.C.E.I. M14x35 UNI-5931 8.8
Washer Schnorr 14
Gasket for auxiliary ange FR1
Screw T.C.E.I. M8x20 UNI-5931 8.8
MULTI-COMPONENTS
Bell-Housing
111